The low-temperature TERMATA LPS heat generator is an autonomous, thermally insulated heater consisting of a heat exchange unit, an automatic block burner operating on natural gas or diesel fuel, and a low- or medium-pressure fan.
The three-flow design of the heat generator's heat exchange unit creates a stream of dry hot air, which finds application in various industrial sectors, such as steaming reinforced concrete products, heating petroleum products along routes, drying grain crops, and more. The heat exchange unit is made of heat-resistant stainless steel, which is resistant to high temperatures and corrosion.
Modification year — 2016
- Таблица 1
Model LPS 95 LPS 110 LPS 140 LPS 170 LPS 195 LPS 260 LPS 290 LPS 360 Total power, kW 85 100 120 150 180 230 260 300 Type of fuel Diesel fuel, natural gas Maximum diesel fuel consumption, kg/h 4,2 8,7 9,7 12,4 15,5 22 25,3 28,5 Maximum natural gas consumption, m³/h 5,4 9,9 10,8 13,2 18,8 28,3 32,8 37,6 Power supply, V/Ph/Hz 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 Maximum outlet air temperature, ºC 90 90 90 90 90 90 90 90 Efficiency, % 92 92 92 92 92 92 92 92 Air output, m³/h 7000 8500 9500 12000 14000 19300 22100 25000 Pressure, Pa 2200 2200 2200 2200 2200 2200 2200 2200 Consumed electrical power, kW 1,5 2,2 2,2 3,3 3,3 5 5 7,5
- Таблица 2
Model LPS 95 LPS 110 LPS 140 LPS 170 LPS 195 LPS 260 LPS 290 LPS 360 Total length, L 1010 1010 1460 1460 1960 1960 2410 2410 Total width, B 2170 2170 2170 2170 2170 2170 2170 2170 Total height, H 2080 2080 2080 2080 2080 2080 2080 2080 D1 180 180 250 250 250 250 250 250 D2 400 400 500 500 500 500 500 500 D3 130 130 130 130 130 130 130 130 F 1320 1320 1320 1320 1320 1320 1320 1320 H1 1900 1900 1900 1900 1900 1900 1900 1900 S1 800 800 1250 1250 1750 1750 2200 2200 S2 1025 1025 1025 1025 1025 1025 1025 1025 - Таблица 3
- The TERMATA LPS heat generator is an automated system with a user-friendly control interface, requiring no constant personnel presence. The automation allows monitoring of the operating cycle status on the device's screen, a PC, or in real-time online. The heat generator can be installed either indoors or outdoors. Its compact size does not demand special installation conditions and also allows for easy relocation if necessary.
Model LPS 95 LPS 110 LPS 140 LPS 170 LPS 195 LPS 260 LPS 290 LPS 360 Total power, kW 85 100 120 150 180 230 260 300 Type of fuel Diesel fuel, natural gas Maximum diesel fuel consumption, kg/h 4,2 8,7 9,7 12,4 15,5 22 25,3 28,5 Maximum natural gas consumption, m³/h 5,4 9,9 10,8 13,2 18,8 28,3 32,8 37,6 Power supply, V/Ph/Hz 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 Maximum outlet air temperature, ºC 90 90 90 90 90 90 90 90 Efficiency, % 92 92 92 92 92 92 92 92 Air output, m³/h 7000 8500 9500 12000 14000 19300 22100 25000 Pressure, Pa 2200 2200 2200 2200 2200 2200 2200 2200 Consumed electrical power, kW 1,5 2,2 2,2 3,3 3,3 5 5 7,5
Model LPS 95 LPS 110 LPS 140 LPS 170 LPS 195 LPS 260 LPS 290 LPS 360 Total length, L 1010 1010 1460 1460 1960 1960 2410 2410 Total width, B 2170 2170 2170 2170 2170 2170 2170 2170 Total height, H 2080 2080 2080 2080 2080 2080 2080 2080 D1 180 180 250 250 250 250 250 250 D2 400 400 500 500 500 500 500 500 D3 130 130 130 130 130 130 130 130 F 1320 1320 1320 1320 1320 1320 1320 1320 H1 1900 1900 1900 1900 1900 1900 1900 1900 S1 800 800 1250 1250 1750 1750 2200 2200 S2 1025 1025 1025 1025 1025 1025 1025 1025
- The TERMATA LPS heat generator is an automated system with a user-friendly control interface, requiring no constant personnel presence. The automation allows monitoring of the operating cycle status on the device's screen, a PC, or in real-time online. The heat generator can be installed either indoors or outdoors. Its compact size does not demand special installation conditions and also allows for easy relocation if necessary.